The analog input module processes signals of a standard magnitude 0–10V. - The input signal is electrically isolated and is transmitted with a resolution of 12 bits. - The internal system supply po...
The analog input module processes signals of a standard magnitude 0–10V. - The input signal is electrically isolated and is transmitted with a resolution of 16 bits. - The internal system supply po...
The analog input module powers the transducers, receives transmitted analog signals, and with electrical isolation, transmits the signals to the fieldbus. The 24V supply for the field is derived fr...
Analogue Input Module, Dimensions W x H x D: 12 x 64 x 100 mm, Inputs: 2 analogue (± 10 V differential input), Inputs, abbreviated: 2 AI (± 10 V differential input), Operating temperature: 0...+55 ...
The analog input module processes signals of a standard magnitude 0–10V. The input signal is electrically isolated and is transmitted with a resolution of 12 bits. The internal system supply powers...
The analog input module receives signals with the standardized values of 0-10V. The input signal is electrically isolated and will be transmitted with a resolution of 12 bits. The internal system v...
The analog input module processes signals of a standard magnitude 0–20mA. The input signal is electrically isolated and is transmitted with a resolution of 12 bits. The internal system supply power...
The analog input module processes signals of a standard magnitude 4–20mA. The input signal is electrically isolated and is transmitted with a resolution of 12 bits. The internal system supply power...
The analog input module processes signals of a standard magnitude 4–20mA. The input signal is electrically isolated and is transmitted with a resolution of 12 bits. The internal system supply power...
The analog output module generates signals of a standard magnitude 4–20mA. The output signal is electrically isolated and transmitted with a resolution of 12 bits. Power is derived from the field s...
Analogue expansion unit, Dimensions W x H x D: 86 x 110 x 50 mm, Inputs: 2 analogue (0/1...5 V, -10/0..+10 V, 0/4...20 mA), Inputs, abbreviated: 2 AI (0/1...5 V, -10/0..+10 V, 0/4...20 mA), Operati...
The analog output module generates signals of a standard magnitude 4–20mA. The output signal is electrically isolated and transmitted with a resolution of 12 bits. Power is derived from the field s...
The analog output module generates signals of a standard magnitude ±10V. The output signal is electrically isolated and transmitted with a resolution of 12 bits. The internal system supply powers t...
Item description: The analog output module generates signals of a standard magnitude 0–10V. The output signal is electrically isolated and transmitted with a resolution of 12 bits. The internal sys...
CPU unit, Dimensions W x H x D: 95.4 x 84.5 x 62 mm, Operating temperature: 0...+55 °C, Certification: CE, cULus, Lloyd, NK , Communications interface: USB 2.0, Data memory: 64 kWords, Inputs/outpu...
Compact PLC, Dimensions W x H x D: 90 x 90 x 86 mm, Inputs: 14 digital, 6 high speed counter, Inputs, abbreviated: 14 DI, 6 HS, Operating temperature: 0...+55 °C, Outputs: 10 relay, Outputs, abbrev...
Digital Input Module, Dimensions W x H x D: 70 x 100 x 75 mm, Inputs: 16 digital, Inputs, abbreviated: 16 DI, Operating temperature: 0...+55 °C, Operating voltage: 24 VDC, Series: SIMATIC S7, No. o...
The digital input module provides 8 channels in a width of just 12mm (0.47in.). It receives control signals from digital field devices (e.g., sensors). Each input module has a noise-rejection filte...
Digital Output Module, Dimensions W x H x D: 70 x 100 x 75 mm, Operating temperature: 0...+55 °C, Outputs: 4 transistor, Outputs, abbreviated: 4 TO, Operating voltage: 24 VDC, Series: SIMATIC S7, N...
This digital output module transmits control signals from the automation device to the connected actuators. All outputs are short-circuit-protected. Field and system levels are electrically isolated.
This digital output module transmits control signals from the automation device to the connected actuators. All outputs are short-circuit-protected. Field and system levels are electrically isolated.
This digital output module transmits control signals from the automation device to the connected actuators. All outputs are short-circuit-protected. Field and system levels are electrically isolated.
The digital output module provides 8 channels in a width of just 12mm (0.47in.). The connected load is switched via digital output from the control system. All outputs are short-circuit-protected. ...
After the fieldbus node is assembled with the correct buscoupler and I/O modules, the end module is snapped onto the assembly. It completes the internal data circuit and ensures correct data flow.
Fail-safe CPU, Dimensions W x H x D: 110 x 100 x 75 mm, Inputs: 14 digital, 2 analogue, Inputs, abbreviated: 14 DI, 2 AI, Operating temperature: 0...+55 °C, Data memory: 125 kB, Inputs/outputs, max...
Fail-safe CPU, Dimensions W x H x D: 130 x 100 x 75 mm, Inputs: 14 digital, 2 analogue, Inputs, abbreviated: 14 DI, 2 AI, Operating temperature: 0...+55 °C, Outputs: 2 analogue, Outputs, abbreviate...
Field Side Connection Module, Dimensions W x H x D: 12 x 64 x 100 mm, Operating temperature: 0...+55 °C, Series: WAGO 750, Protection rating: IP 20, Termination type: CAGE CLAMP Connection, No. of ...
The 750-354 EtherCAT Fieldbus Coupler connects EtherCAT to the modular WAGO-I/O-SYSTEM. The fieldbus coupler automatically configures, creating a local process image which may include analog, digit...
Fieldbus Coupler, Dimensions W x H x D: 51 x 65 x 100 mm, Operating temperature: 0...+55 °C, Communications interface: PROFIBUS DP, D-Sub, Operating voltage: 24 VDC, Series: WAGO 750, Switching cap...
The WAGO‐I/O-SYSTEM 750 can also be used in shipbuilding applications and onshore/offshore installations (e.g., platforms, loading facilities). This is possible via certification under the standard...
Incremental Encoder Interface, Dimensions W x H x D: 24 x 64 x 100 mm, Operating temperature: 0...+55 °C, Operating voltage: 24 VDC, Series: WAGO 750, Protection rating: IP 20, Termination type: CA...
LOGO! CMR2040 communication module for connection LOGO! 8 to LTE network; 1 RJ45 port for Ind. Ethernet connection to LOGO! 8; 2xDI; 2xDQ; Write/read access to LOGO! tags; Text message sending/ rec...